HD 22.2 S2 A9-1993 Rubber Insulated Cables of Rated Voltages up....pdf
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD 22.2 S2 A9-1993 Rubber Insulated Cables of Rated Voltages up. A9 1993 up
- 资源描述:
-
3404583 0085590 153 = CENELEC Rum de Staiiart. 35 - B 1050 BruxellOi Tbl.: (+ 32 2) 518.88.71 - Fax: (+ 32 2) 5lS.OQ.lS INFORMATION SHEET HD 22.2 S2lA9 Issue 1 1993-10-22 I October 1993 Rubber insulated eables o f rated voltages up to and including 4501750 V Part 2: Test methods Conducteurs et cables isols au Isolierte Starkstromleitungen mit caoutchouc, de tension assigne au einer Isolierung aus Gummi mit plus egale a 4501750 V Nennspannungen bis 4501750 V Deuxieme partie: Hethodes dessais Teil 2: Prfverfahren Related to Directive: 73123JEEC This amendment consists of the following: - Title Page - Text prepared by CENELEC Technical Committee TC 20 date of ratification : 1993-09-22 date of announcement : 1994-03-01 date of latest publication : 1991-09-01 date of withdrawal : 1994-09-01 LIST OF NATIONAL STANDARDS, IF ANY, IS GIVEN OVERLEAF 3404583 0085593 09T = I AARHONIZATION DOCUHENT DOCUMENT DHARMONISATION HARHONISIERUNGSDOKUMENT HO 22.2 S21A9 October 1993 UDC 621.315.211.2.027.475.001.4 Descriptors: See HO 22.2 S2:1992 ENGLISH VERSION Rubber insulated cables of rated voltages up to and including 4501750 V Part 2: Test methods Conducteurs et cables isols Isolierte Starks-romlei-ungen au caoutchouc, de tension mit einer Isolierung aus Gummi assignee au plus egale a 4501750 V mit Nennspannungen bis 4501750 V Deuxime partie: Mthodes Teil 2: Prfverfahren dessais This amendment A9 modifies the Harmonization Document HD 22.2 S2:1992. It was approved by CENELEC on 1993-09-22. CENELEC members are bound to comply with the CEN/CENELEC Inernal Regulations which stipulate the conditions for implementation of this amendment on a national level. Up-to-date lists and bibliographical references concerning national implementation may be obtained on application to the Central Secretariat or to any CENELEC member. This amendment exists in three official versions (English, French and German). CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comite Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 3 5 , 8-1050 Brussels 1993 Copyright reserved to CENELEC members Ref. No. HD 2 2 . 2 S2:19921A9:1993 E _ _ _ _ _ 3404583 0085572 T2b m Page 2 HD 22.2 S2:1992/A9:1993 FOREWORD Following a decision taken by CENELEC Technical Committee TC 20, Electric cables, an amendment to HD 22.2 S2:1992 was submitted to the CENELEC Unique Acceptance Procedure (UAP) in November 1992. The text of the draft was approved by CENELEC as amendment A9 to HD 22.2 S2 on 22 September 1993. The following dates were fixed: - latest date of announcement of the amendment at national level (doa) 1994-03-01 - latest date of publication of a harmonized national standard - latest date of withdrawal of conflicting national standards (dopl 1994-09-01 (dew) 1994-09-01 For products which have complied with HD 22.2 S2:1992 and its amendments A5:1992 to A8:1993 before 1994-09-01, as shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 1995-09-01. W 3404583 0085593 962 Page 3 HD 22.2 S2: 1 992/A9: 1 993 Sub-clause 2.6 Amend paragraph 2 to read: The test shall be either, (i) for unsheathed or sheathed single core cables, a spark test in accordance with Part 2 sub-clause 2.6.1, or, ( i i ) for multicore cables, a voltage test in accordance with Part 2 sub-clause 2.6.2. Sub-clause 2.6.1 Add to sub-clause 2.6.1 the following: When sheathed single core cables are tested in accordance with this sub-clause, the efficacy of the spark testing equipment shall be determined by reference to the thickness of insulation only. For the purposes of testing sheathed single core cables, all references in Part 2 Appendix 1 to insulation, except where it refers to the determination of the diameter of the calibration hole (second sentence of sub-clause 2.2(d), shall be interpreted as meaning the combination of insulation and sheathing.展开阅读全文
文档分享网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



链接地址:https://www.wdfxw.net/doc91810685.htm