书签 分享 收藏 举报 版权申诉 / 4

类型SEMI C3.39-0999 STANDARD FOR NITROGEN TRIFLUORIDE (NF3).pdf.pdf

  • 上传人:ngng6006
  • 文档编号:51007463
  • 上传时间:2017-06-17
  • 格式:PDF
  • 页数:4
  • 大小:42KB
  • 配套讲稿:

    如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。

    特殊限制:

    部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。

    关 键  词:
    SEMI C3.39-0999 STANDARD FOR NITROGEN TRIFLUORIDE NF3.pdf C3 39 0999 NF3 pdf
    资源描述:
    SEMI C3.39-0999 SEMI 1989, 19991 SEMI C3.39-0999 STANDARD FOR NITROGEN TRIFLUORIDE (NF3) This standard was technically approved by the Global Gases Committee and is the direct responsibility of the North American Gases Committee. Current edition approved by the North American Regional Standards Committee on October 18, 1998.Initially available on SEMI OnLine August 1999; to be published September 1999. Originally published in 1989; previously published in 1996. 1 Description 1.1 Nitrogen trifluoride is a toxic, odorless, colorless, nonflammable gas. It is a strong oxidizer and supports combustion. 2 Specifications 2.1 QUALITY: 99.98% ImpuritiesMaximum Acceptable Level (ppm) (see NOTE 1) Carbon Dioxide (CO2)10 Carbon Monoxide (CO)10 Carbon Tetrafluoride (CF4)100 Nitrogen (N2)10 Nitrous Oxide (N2O)10 Argon/Oxygen10 Sulfur Hexafluoride (SF6)10 Water (H2O) (v/v)1 TOTAL IMPURITIES161 (see NOTE 1) NOTE 1: An analysis of significant figures has not been considered. The number of significant figures will be based on analytical accuracy and the precision of the provided procedure. 3 Chemical Specification Hydrolyzable Fluorides as HF1 ppm 4 Physical Constants (for information only) Metric UnitsUS Units Molecular weight71.0071.00 Density of gas at 21.1C (70F) and 1 atm 2.94 kg/m30.1838 lb./ft.3 5 Analytical Procedures 5.1 Carbon Tetrafluoride This procedure is for the determinationofcarbontetrafluorideinnitrogen trifluoride using a gas chromatograph with a thermal conductivity detector. (See Figure 1 and Note 1.) 5.1.1 Detection Limit 1.0 ppm. 5.1.2 Instrument Parameters 5.1.2.1 Column: Super Q (80/100 mesh), 4.9 m (16 ft.) by 1.75 mm (1/16 in.) ID, 3.2 mm (1/8 in.) OD ss or equivalent. 5.1.2.2 Carrier Flow: 19 mL/min helium. 5.1.2.3 Sample Volume: 0.1 mL. 5.1.2.4 Temperatures: Detector100C Oven42C Gas sampling valve42C 5.1.2.5 Valve material: Nitronic-60 or equivalent. 5.1.3Calibration Standard 100 ppmcarbon tetrafluoride, balance helium. 5.1.4 Operating Procedure 5.1.4.1 Inject the calibration standard into the column using a gas sampling valve. Record retention time and peak area. 5.1.4.2 Inject nitrogen trifluoride sample to be tested in the same manner as the calibration standard. Record the retention times and peak areas. 5.1.4.3 Repeat 5.1.4.1. 5.1.4.4Comparetheaveragepeakareaofthe calibration standard to that of the nitrogen trifluoride sample being tested. Calculate the concentration of carbon tetrafluoride, using the formula below. The result may not exceed the specification in Section 2 of this Standard. Sample Peak Area Standard Peak Area Concentration of Standard = Concentration of Sample 5.2Carbon Dioxide, Nitrous Oxide,andSulfur Hexafluoride This procedure is for the determination ofcarbondioxide,nitrousoxide,andsulfur hexafluorideinnitrogentrifluorideusingagas chromatograph with a thermal conductivity detector. (See Figure 1.) 5.2.1 Detection Limit 1.0 ppm for carbon dioxide, nitrous oxide, and sulfur hexafluoride. 5.2.2 Instrument Parameters 5.2.2.1 Column: Super Q (80/100 mesh), 4.9 m (16 ft.) by 1.75 mm (1/16 in.) ID, 3.2 mm (1/8 in.) OD ss or equivalent. SEMI C3.39-0999 SEMI 1989, 19992 5.2.2.2 Carrier Flow: 19 mL/min helium. 5.2.2.3 Sample Volume: 1.0 mL. 5.2.2.4 Temperatures: Detector100C Oven42C Gas sampling valve42C 5.2.2.5 Valve Material: Nitronic-60 or equivalent. 5.2.3 Calibration Standard 10 ppm carbon dioxide, 10 ppm nitrous oxide, 10 ppm sulfur hexafluoride, balance helium. 5.2.4 Operating Procedure 5.2.4.1 Inject the calibration standard into the column using a gas sampling valve. Record the retention times and peak areas. The order of elution is carbon dioxide, nitrous oxide, sulfur hexafluoride. (See Figure 1 for valve configuration.) 5.2.4.2 Inject the sample to be tested in the same manner as the calibration standard. Record the retention times and peak areas. 5.2.4.3 Repeat 5.4.2.1. 5.2.4.4Comparetheaveragepeakareaofthe calibration standard to that of the nitrogen trifluoride sample being tested. Calculate the concentration of each impurity using the formula below. The results may not exceed the specifications in Section 2 of this Standard. Sample Peak Area Standard Peak Area Concentration of Standard = Concentration of Sample 5.3 Carbon Monoxide This procedure is for the determinationofcarbonmonoxideinnitrogen trifluoride using a gas chromatograph with a methanizer and a flame ionization detector. (See Figure 1 and Note 2.) 5.3.1 Detection Limit 0.1 ppm. 5.3.2 Instrument Parameters 5.3.2.1 Column: Carbosphere (80/100 mesh), 0.74 m (2.4 ft) by 1.75 mm (1/16 in) ID, 3.2 mm (1/8 in) OD ss or equivalent. 5.3.2.2 Carrier Flow: 25 mL/min helium. 5.3.2.3 Sample Volume: 0.5 mL. 5.3.2.4 Fuel gases: Hydrogen:Zero grade or better hydrogen at a flow rate of 45 mL/min is added to the carrier gas between the column outlet and the methanizer inlet. Air:Zero grade or better air is used at a flow rate of 300 mL/min. 5.3.2.5 Temperatures: Detector150C Oven42C Methanizer340C Gas sampling valve70C 5.
    展开阅读全文
    提示  文档分享网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
    关于本文
    本文标题:SEMI C3.39-0999 STANDARD FOR NITROGEN TRIFLUORIDE (NF3).pdf.pdf
    链接地址:https://www.wdfxw.net/doc51007463.htm
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    版权所有:www.WDFXW.net 

    鲁ICP备09066343号-25 

    联系QQ: 200681278 或 335718200

    收起
    展开